PBM Motor and Fan is a China mainland manufacturer and EC technology consulting company offering an extensive range of EC(Electronically Commutated) motors, fans and solutions, investing in the latest developing, manufacturing and technical equipment with in-depth processes & procedures. Our main products are EC fans, including EC axial fans, EC centrifugal fans and EC blowers. We do both AC and DC current type. And EC Motor is the core technology of our products.
Eletronically Commutated Motors(EC Motors)also known as Brushless DC Motors(BLDC) are synchronous electric motors powered by direct-current(DC) electricity and having electronic commutation systems,rather than mechanical commutators and brushes.The current-to-torque and voltage-to-speed relationships of BLDC motors are linear.
PBM fans are widely used in many fields. For example, axial fan for telecom, backward curved centrifugal fan for air exchanger,(inline duct fan)hydroponic products and FFU, forward curved centrifugal fan for air purifier and air conditioning,blower for kitchen.
1.General Characters
1–1 |
Rated Voltage |
48 VDC |
1–2 |
Operating Voltage |
36~57 VDC |
1–3 |
Low-Start Voltage |
30VDC |
1–4 |
Rated Speed |
4600RPM |
1–5 |
Input Current |
2.1A |
1–6 |
Input Power |
100W |
1–7 |
Air Flow |
544CFM / 925m3/H |
1–8 |
Static Pressure |
2.8inH2O / 709Pa |
1–9 |
Acoustical Noise |
68 dB(A) |
1–10 |
Life Expectance |
50,000Hours(L10) At 40℃ room, humidity 15%~65%RH. |
1–11 |
Direction of Rotation |
clockwise seen on motor |
1–12 |
Direction of Air Flow |
Axial |
1–13 |
Insulation Class |
Class B |
1–14 |
Insulation Resistance |
50 Mega Ohm minimum at 500VDC Between frame and (+) terminal |
1–15 |
Motor Protection |
Locked rotor protection Polarity protection Automatic restart capability |
1–16 |
Speed Control |
Control input 0~10VDC / PWM |
1–17 |
Protection Type |
IP44 |
1–18 |
Dielectric Strength |
10mA maximum at 1000VAC 50Hz five second Between frame and (+) terminal |
1-19 |
Signal Output |
FG (Frequency Generator) |
2. Mechanical Characters
2–1 |
Dimension |
Ø200mm X 70mm(see dimension drawing) |
2–2 |
Material of Impeller |
Propylene with glass-fiber reinforced |
2–3 |
Number of Blades |
5 |
2–4 |
Impeller Plate |
No |
2–5 |
Mounting Position |
Any |
2–6 |
Surface of Rotor |
Coated in black |
2–7 |
Bearing System |
NMB ball bearing |
2–8 |
Lead Wire |
AWG20# |
2–9 |
Weight |
1800 g |
2–10 |
Package |
Standard |
3. Electrical Protection
3–1 |
Locked-rotor Protection |
Over-current limiting circuit protects motor from damage at least for 72 hours of locked rotor condition at rated voltage. |
3–2 |
Maximum Current under Locked Rotor
|
A, Typical inrush current when the motor is trying to re-start under locked rotor conditions is 2~4 times the normal running current reoccurring and for 16~20% of restarting cycle period. B, If he CL function is used this restarting inrush current is about the same as the normal running current. |
3–3 |
Reverse Polarity Protection |
No damage if the positive and negative leads are reversed under maximum operation voltage conditions. |
3–4 |
Over Voltage Protection |
The circuit will be shut down automaticlly when input voltage over 60VDC. And re-started when Voltage down to 60VDC below. |
3–5 |
Soft Start |
In 5 seconds after power on and speed control voltage gets to 1.5V or PWM duty cycle at 10% above. |
4. Environmental Characters
4–1 |
Operating Temperature |
-25℃ to 60℃ |
4–2 |
Storage Temperature |
-40℃ to 75℃ |
4–3 |
Operating Humidity |
5% to 90% RH |
4–4 |
Storage Humidity |
5% to 95% RH |
4–5 |
Drop Test |
In minimum packaging condition fan withstand each one drop of three faces from 30cm distance height onto 10mm thickness of wooden board. |
4–6 |
Vibration Test |
Sine Wave. Displacement amplitude: 0.75mm (Equivalent 10G). Frequency Range: 10Hz~55Hz / 30 sec. 55Hz~10Hz / 30 sec Linear Scanning 120 Cycle Endurance timer per axis: 2 Hours Orientation: X,Y,Z. |
4–7 |
Shock Test |
Apply peak acceleration 50g and keep duration of the pulses for 11ms (Half sine wave). |
4–8 |
Dustproof Test |
Temperature range: 15℃ to 35℃. 1mm diameter metal wire cannot go through the gap between rotor cup and base. Follow IEC 60592 IP4X. |
4–9 |
Waterproof Test |
Temperature range: 15℃ to 35℃ and duration of test: at least 10 minutes, to spray water from all direction (360°). Follow IEC 60529 IPX4 |
4–10 |
RoHS |
All the material meets RoHS standard. |
Sepecification
PBM Motor and Fan is a China mainland manufacturer and EC technology consulting company offering an extensive range of EC (Electronically Commutated) motors, fans and solutions, investing in the latest developing, manufacturing and technical equipment with in-depth processes & procedures. We are able to stay at the forefront of EC motor and fan market and offer high quality & economical products, to many of the worldwide leading ventilation & refrigeration Original Equipment Manufacturers.